Lab Conditioning Chamber i10 (Touch Panel)
Next Generation Accurate Lab Conditioning Chamber with touch Panel
Paramount Lab Conditioning Chamber i10 (Touch Panel) is a highly advanced next generation equipment to maintain the standard Atmospheric condition for the conditioning of sample accurately & consistently. It has a test chamber
With Paramount you're always in safe hands with our
Lifetime Buyback Warranty


In Textile testing, all the fabric samples should be conditioned keeping the sample in standard Atmospheric condition (22°±1° C Temperature & 65%±2% RH) prior to perform the test to get the accurate test result.
Paramount Lab Conditioning Chamber i10 (Touch Panel) is a highly advanced next generation equipment to maintain the standard Atmospheric condition for the conditioning of sample accurately & consistently. It has a test chamber of triple walled construction. The inner walls are made of special grade Stainless-Steel sheet and outer walls of mild steel sheet. The chamber is fitted with three perforated Stainless-Steel shelves for keeping the Test Specimen. The cooling in the chamber is attained by an advanced cooling system with the help of a sealed compressor , An air-circulating Fan with heater is provided on back side of the chamber to enable uniform temperature & Humidity in the whole chamber. All the functions is controlled by with a programmed HMI (Human Machine Interface) and PLC (Programmable logical controller) The temperature inside the test chamber is also controlled with the help of programmable HMI and PLC. D-65 light is provided in the Chamber to view the samples during conditioning.

- ASTM D1776
- ISO 187
- ITMF PGA
- ISO 139
- DIN 5015
- ERT 60-1

- Very Accurate equipment to accomplish perfect temperature and humidity conditions in the unit
- Intuitive touch control panel with PLC controller for precise control of temperature and humidity
- Triple wall construction with all interiors of SS 34
- Highly accurate temperature and humidity sensors
- Real time data display and recording of temperature and humidity
- Run time V/s humidity graph
- With all safety features: High temp. cut off. Low water cut off.
Electrical circuit breaker etc
- Transparent glass window to see the sample.
- One D 65 light fitted inside the chamber for viewing the sample.
- Three perforated trays supplied with the equipment to keep the samples properly inside the chamber.
- Caster wheel at base for easy movement.
- Failure warning Indicated by Switch.
- Supplied complete with Calibration Certificate (Traceable to NPL).

Power Supply | 230 Volt Ac, 50 Hz, Single Phase |
Chamber Size | 500 (L) x 500 (W)x 600(H) mm |
Capacity | 150 Litres |
Temperature Range | 10 – 70 °C±1°C |
Humidity | 20 – 98 % ±2 % |
Heating Time | 3°C / Minute |
Cooling Time | 1°C / Minute |
Standard Temperature for Textile | 22°±2°C |
Tray Size | 450 mm x 480 mm |
Standard Humidity for Textile | 65 % ±2 % |
Overall Dimensions of the unit | LENGTH x DEPTH x HEIGHT 150mm x 1000mm x 1650mm |